| Problem |
Cause |
Solution |
| Unit will not heat up. |
No power to unit. |
Make sure power cord plugged into the unit and
proper electrical receptacle. |
| Inoperable power cord. |
Replace power cord. |
| Loose connection on power switch. |
Tighten power switch connections. |
| Inoperable power switch. |
Replace power switch. |
| High limit switch tripped. |
Reset limit switch. Using a pencil or pen, press
the hollow portion of the 3/8" long brown, plastic
stem located at the right-hand rear of the unit.
Allow the unit to cool (approximately 15 minutes)
before starting.
|
| Unit heats up but conveyor will not run. |
Loose motor connection. |
Tighten motor connection. |
| Inoperable motor. |
Replace motor. |
| Stripped drive gear. |
Replace drive gear. |
| High limit switch tripped. |
Reset limit switch. Allow the unit to cool
(approximately 15 minutes) before starting.
|
| Buns under or over done. |
Check bun crush setting. |
Adjust for proper compression. |
| Verify setpoint temperature. |
Adjust setpoint for proper temperature. |
| Dirty teflon sheet. |
Clean or replace teflon sheet.
|
|
|