| Problem |
Cause |
Solution |
| 1. Power Light Off. |
Circuit Breaker Off. |
Check and Reset. |
| Unit Not Plugged In. |
Plug In Cord. |
| Power Switch Off. |
Turn To On Position. |
| Inoperable Power Switch. |
Replace Power Switch. |
| Loose Wires. |
Check All Wire Connections. |
| Inoperable Power Light. |
Replace Power Light.
|
| 2. No Heat. |
Circuit Breaker Off. |
Check and Reset. |
| Unit Not Plugged In. |
Plug in Cord. |
| Power Switch Off. |
Turn To On Position. |
| Inoperable Thermostat. |
Place Both Thermostat Wires on Same Terminal. If Platen
Heats Replace Thermostat. |
| Inoperable Platen. |
Take An Ohm Reading Across the Two Platen Calrods
and verify 11 Ohms. If Not Replace Platen.
|
| 3. No Audible Or Visual Alarm. |
Inoperable Activating Switch. |
Replace Activating Switch. |
| Inoperable Timer. |
Replace Timer.
|
4. No Audible Alarm.
|
Inoperable Buzzer. |
Replace Buzzer. |
| 5. Buns Toasting Too Light. |
Platen Temperature Too Low. |
Verify Platen Temperature and Adjust Potentiometer To
Proper Temperature. |
| Not Enough Bun Compression. |
Adjust Stop Blocks Until You Recieve Proper Compression.
|
| 6. Buns Toasting Too Dark. |
Platen Temperature Too High. |
Verify Platen Temperature and Adjust Potentiometer To
Proper Temperature. |
| Inoperable Thermostat. |
If Platen Temperature Can Not Be Adjusted Replace The
Thermostat. |
| Inoperable Timer. |
Check Timer and Verify The Countdown Time, If Wrong
Adjust Timer To The Right Setting, Or Replace The Timer.
|
| 7. Buns Sticking. |
Platen Temperature Too High. |
Verify Platen Temperature and Adjust Potentiometer. |
| Too Much Compression. |
Check Stop Blocks and Adjust To Correct Setting. |
| Dirty Platen. |
When Cool Remove Excess Carmelization With A Damp
Cloth and A Non-Abrasive Cleaner.
|